Sl. |
ITEM DESCRIPTION |
PROCEDURE |
MATERIAL (See Sample) |
PRE-CONSTRUCTION WORKS |
|||
|
Area Mapping |
Done by Manual measuring
tools and tackles or by Total Station |
N/A |
|
Architectural
Plan |
Preparation
of Layout Plan, Column Centre Line Plan, D/W Schedule |
N/A |
|
Structural Design |
Preparation of Footing
Details, Column Schedule, All Beam Details, Roof Slab Details, All BBS & other critical
designs if required. |
N/A |
|
3D
Views |
Preparation
of 3D Elevation views |
N/A |
CORE STRUCTURE |
|||
|
Earth
work in ambient Soil conditions (Hard Strata found within a depth of 2Mtr)
with in 25 Mtr Initial Lead and 2 Mtr Initial Lift, including Rough Dressing. |
Excavation
Up to Size 5' X 5' X 4' or less as per Structural Requirements, done manually
or by mechanical Means. |
N/A |
or |
Earth work in Loose soil
conditions (Hard Strata found beyond a depth of 2 Mtr) with in 25 Mtr Initial
Lead and 2 Mtr Initial Lift, including Rough Dressing |
Pilling up to suitable
depth using Auger Boring technique. 10" Manual Excavation above blunt
pile heads. N.B: Pilling Works shall be charged
Extra including labour and Material Charges as on actual. |
PPC Cement Sand Coarse Aggregates |
|
Sand
Filling |
4"
Filling of Sand including watering & Ramming done Manually or
Mechanically. |
Sand |
|
PCC |
4" PCC (1:4:8)
Concreting and then Placing of Column Reinforcement over single or double
layered reinforcement mat all as per BBS & CS. |
PPC Cement Coarse Sand Coarse Aggregates |
|
RCC
Footing and Column up to Plinth Level. N.B: Up to
2' above existing average ground
level is covered under the package above that shall be charged extra. |
Trapezoidal
Footing or Pedestal concreting over pile cap as per foundation plan and
structural Requirement, Checked & verified by Structural Consultant. |
PPC
Cement TMT
Steel Sand Coarse
Aggregates |
|
Masonry Work up to bottom
of Plinth beam |
Manual Excavation up to
1' below existing Ground Level. 100 mm Sand Filling & 100 mm PCC (1:4:8).
Stone masonry work. |
PPC Cement Sand Coarse Aggregates Laterite Stone |
|
Backfilling
(Up to Plinth Level) N.B: Up to 2' above
existing average ground level is covered under the package above that shall
be charged extra. |
Watering
and compacting up to required Density. Up to 2' Above Existing Avg. Ground
Level. |
Locally
Available Backfilling Materials |
|
Tie Beam |
Reinforcement, Beam side
Shuttering and concreting As per structural Requirement, Checked by
Structural Consultant. |
PPC Cement TMT Steel Sand Coarse Aggregates |
|
Water
Proofing |
Compound
mix with mortar for plaster & Punning work below plinth as per
Manufacturer Specification. |
Water
Proofing Compound |
|
Anti Termite Treatment |
Compound mix with water
gently sprayed at plinth level before flooring as per Manufacturer
Specification |
Anti Termite Chemical
(Str) |
|
Plinth
level Sand filling and Floor PCC |
6"
Sand Filling, watering and Ramming 4"
PCC (1:4:8) Concreting keeping proper Slope Gradient |
PPC
Cement TMT
Steel Sand: Coarse
Aggregates |
|
Column (Up to Lintel
Level) |
Shuttering, reinforcement
& Casting of Column As per structural Requirement, Checked and Verified
by Structural Consultant. |
PPC Cement Steel Sand: River Sand Coarse Aggregate |
|
Brick
Masonry (Up to Lintel Level) |
Brick
Masonry of 250 mm thick for external wall & 125 mm thick for Partition wall. |
Cement Sand:
River Sand Standard
Fly Ash Bricks |
|
Sill Level Casting in
case of Windows |
Shuttering, reinforcement
& Casting with Minimum Projection of 250 mm and bearing As per structural
Requirement, Checked by Structural Consultant. Height ranging from 0.75 -
0.90 mtr. |
PPC Cement TMT Steel Sand: River Sand Coarse Aggregate |
|
Lintel
Level Casting N.B: Cut Size in case of Openings is covered in this package. |
Shuttering,
reinforcement & Casting in cut size with and bearing As per structural
Requirement, Checked by Structural Consultant. |
PPC
Cement TMT
Steel River
Sand Coarse
Aggregate |
|
External Projection |
Shuttering, reinforcement
& Casting with external Projection ranging from of 250- 300 mm and bearing As per
structural Requirement, Checked by Structural Consultant. |
PPC Cement TMT Steel Sand: River Sand Coarse Aggregate |
|
Brick
Masonry (Up to Slab Level) |
Brick
Masonry of 250 mm thick for external wall & 125 mm thick for Partition wall. |
PPC
Cement River
Sand Standard
Fly Ash Bricks |
|
Slab less Stair Case |
Shuttering, hook type
reinforcement and casting with Tread Size 250 mm X 1200 mm and Minimum Riser
Height of 150 mm. As per structural Requirement, Checked & Verified by
Structural Consultant |
PPC Cement TMT Steel River Sand Coarse Aggregate |
|
Roof
Slab Casting |
Shuttering,
Reinforcement and casting of Maximum Thickness 115 mm. All as per structural
Requirement, Checked by & Verified by Structural Consultant. |
Cement TMT Steel River
Sand Coarse
Aggregate Conduits:
PVC Pipes |
|
Same process repeats for
subsequent floors. |
||
|
Terrace
Head Room: If constructed with RCC structure then
rate applicable as per covered Area of Roof. But in case of construction of
temporary structure using GI Sheet and MS Sectional Pipe shall be charged
extra as on actual. |
||
|
Roof Grading |
Placing of Mortar (1:6)
across the terrace slab providing ambient slope towards rain water outlets. |
PPC Cement, River Sand,
Water Proofing Compound. |
|
Terrace
Parapet |
Brick
Masonry 125 mm thick up to Max Height of 500 mm. Using 1:6 Mortar. (N.B: Any type of external elevation design shall be charged
Extra as on actual) |
PPC
Cement Sand:
River Sand Standard
Fly Ash Bricks |
|
Standard Plaster (Exteriors,
Interiors and ceiling) |
20 mm Thick for External
Side & 15 mm Thick for Internal Side using cement mortar 1:6. 6 mm Thick for Ceiling using Cement
Mortar 1:4 |
PPC Cement Sand: River Sand |
|
Design
Plaster |
(N.B: Any type of external elevation design shall be charged
Extra as on actual) |
PPC
Cement Sand:
River Sand |
|
Low Roofs (Internal) |
Kitchen Counter Top, two
Loft of 2' Width and requisite length as per architectural plan any other
type of Low roof construction shall be charged Extra.) |
PPC Cement TMT Steel Sand Coarse Aggregates |
OPENINGS & EDGE PROTECTION |
|||
|
Door Frames |
Door
Frame Fixing using holdfast as per Door & Window Schedule Specifications
with maximum opening size of 1000 mm X 2100 mm. Max. Thickness of Frame shall
be 2.5" and width shall be 4". |
Door Frame: Precast Frame (Cement
Punned Finish & Painted) or Material with equivalent cost. |
|
Window
Frames |
Window Frame Fixing as per Door & Window
Schedule Specifications with Maximum opening size of 1200mm X 1300mm.
Thickness of Frame shall be 2.5" and width shall be 4". |
Window
Frame: Precast
Frame (Cement Punned Finish & Painted) or Material with equivalent cost. |
|
Main Door |
Maximum one unit per
floor. Single shutter of Size as per Door & Window Schedule
Specifications and Design Selected from the Sample. |
Designer type
of Seasoned Wood with lac Polish |
|
Main
Door Fittings and Fixtures |
Door
Fixed with 3 Butt Hinge, 1 Aldrop Bolt, 2 Latch, 1 Tower Bolt, 2 Bow Handle,
Mortise Lock, Door Stopper, PVC Buffer & Door Viewer. |
Brass/
SS/ Aluminium Fittings (N.B: Only 1 Side Brass
Fittings Set for each Main Door is Covered.) |
|
Individual Room Doors |
Single Shutter of size as
per Door & Window Schedule Specifications and Design Selected from the
Samples. |
Membrane Doors/ Fibre Doors /Seasoned Wood |
|
Individual
Room Door Fittings & Fixtures |
Door
Fixed with 2 Butt Hinge, 1 Aldrop Bolt, 2 Latch, 1 Tower Bolt, 2 Bow Handle,
Mortise Lock, Door Stopper, PVC Buffer & Door Viewer. As per Door &
Window Schedule Specifications. |
SS/ Aluminium Fittings |
|
Window |
Sliding/ Double Casement
as per Door & Window Schedule Specifications and Design Selected from the
Samples. |
Composite
Wood- Glass /Composite Powder Coated Aluminium Sliding Window with 5mm Dark
Glass |
|
Window
Fittings and Fixtures |
Window
Fixed with 2 Butt Hinge, 2 Tower Bolt, 1 Bow Handle, 1 Wind Window Hook or
Window Closure & Door Viewer. |
SS/ Aluminium/ PVC Fittings |
|
Bathroom Ventilator |
Horizontally
Pivoted or Louvered type ventilator of size as per Door & Window Schedule
Specifications and designs selected from the samples. |
Composite Wood- Glass
/Composite Powder Coated Aluminium with 5mm Dark Glass |
|
MS
Grills for all Window/ Ventilator Openings |
Either
fixed using holdfast or screwed permanently across supporting structure.
Design & enamel painted as selected from sample. |
MS
Section Grill painted with 1 coat Primer + 2 Coat enamel paint. |
|
Other Openings |
Sky light, AC Vent/ Gas
Vent etc. |
Composite MS Section +
Glass/ Designer Precast |
|
Balcony/
Stair Case Railing |
Fixed
with Anchor Bolts, Maximum Triple Layer and fixed type. Maximum Height shall
be 3'2". |
Stainless
Steel/ Mild Steel Painted. |
FLOORING & PAINTING |
|||
|
Paint
(Interiors) |
2 Coat
Wall Putty + 1 Coat primer + 2 Coat Paint. Water paint ratio as per
manufacturer guideline |
Wall
Putty Primer Paint |
|
Paint (Exteriors) |
1 Coat primer + 2 Coat
Weather Proof Paint. Water paint ratio as per manufacturer guideline |
Primer Paint |
|
Flooring
for All Rooms/ Balconies |
Mortar
placing (1:6), cement Slurry Spreading, tile fixing and grout finish keeping
zero slope gradient. Materials selected from Sample. |
2' x
2' Vitrified Tiles PPC
Cement, Sand, Grouting Compound (Matching Tile Colour) |
|
Bathroom Flooring |
Mortar placing (1:6),
cement Slurry Spreading, tile fixing and joint grout finish keeping slope
gradient towards outlet drain. Materials selected from Sample. |
2' x 2' Ceramic Tiles PPC Cement, Sand,
Grouting Compound (Matching Tile Colour) |
|
Bathroom
and Kitchen Wall Tiling |
Mortar
placing (1:6), cement Slurry Spreading, tile fixing and joint grout finish
keeping zero slope gradient Materials selected from Sample. Maximum Up to 6'
Height |
8"
x 12" Wall Tiles, PPC Cement, Sand, Grouting Compound (Matching Tile
Colour) |
|
Staircase Flooring |
Mortar placing (1:6),
cement Slurry Spreading, fixing and joint grout finish keeping zero slope
gradient Materials selected from Sample. |
Non Polish Marble/
Granite |
|
Kitchen
Counter Top |
Mortar
placing (1:6), cement Slurry Spreading, fixing and joint grout finish keeping
zero slope gradient Materials selected from Sample. |
Granite
Counter Top |
PLUMBING |
|||
|
N.B: In each floor area ranging from 1000 Sqft to 2500 Sqft area,
1 Toilet, 1 Bathroom, 1 Kitchen, 1 Wash Basin are Covered. |
||
|
Common Toilet |
Equipped with S Trap 1
Sitting type Coupled Closet or1 20" Squatting Pan with outdoor PVC
cistern unit (45 x 13 x 30.2 cm), 1 Wall Hung Basins, 1 Pillar Cock (Foam
Flow) Faucet, 1 wall mixer (2 in 1) with provision for overhead shower,
Single Flow Overhead shower,1 Bib Cock Faucet |
All branded sanitary
wares and faucets |
|
Attached
Bathroom |
Equipped
with S Trap 1 Sitting Type Coupled Closet or1 20" Squatting Pan with
outdoor PVC cistern unit (45 x 13 x 30.2 cm), 1 Health Faucet, 1 Wall Hung
Basins, 1 Pillar Cock (Foam Flow) Faucet, 1 wall mixer (3 in 1) with
provision for overhead shower and hand shower, 1 200mm Rain shower, 1 Three
Flow Hand Shower (150 mm), 1 Bib Cock Faucet |
All
branded sanitary wares and faucets |
|
Common Accessories |
1 Soap Dish Holder, Towel
Bar & Bathroom Mirror |
All branded accessories |
|
Kitchen |
1 SS
Single Bowl Kitchen Sink, Sink Cock with normal swivel spout table/ wall
mounted Faucet |
All
branded sink and faucet |
|
Wash Basin |
1 Single lever Basin
Mixer, 1 Full Pedestal or Half Pedestal or Table Top Designer Basins. |
All branded sanitary
wares and faucet. |
|
Plumbing
Pipes Layout |
Laying
out as per Specifications |
UPVC
Pipes, Joint Glue |
|
Sanitary and Rain Water
Pipeline |
One pipe system laying
out as per Specifications |
PVC Pipes, Joint Glue |
ELECTRICAL |
|||
|
Electrical Conducting |
Laying out of Conduit
pipes and installation of Fan Box all as per
Specifications |
PVC Pipe |
|
Electrical
Wiring |
As
per Specifications |
Insulated
Copper PVC Cable. |
|
Switch Points, Bulb
Points, Fan Point |
All main points equipped
with 6 Switch, 1 5A/15A Socket, 1 Regulator, Single Switch points with 5A/ 15
A Points all as per Specifications |
Branded Modular Switches
and points |
|
MAIN
DISTRIBUTION PANEL |
All
points connected to the main distribution box with individual room MCB switch |
Branded
Modular MCB panel Box |
|
N.B: In each
floor a maximum of 2 nos. of 15A Socket and 8 Nos 5A Socket are covered. Earthling
wire is covered under the package but installation of Earthling System is
charged extra as on actual. |