About usContact uswe are Hiring Book Appointment 0 items for Estimate

PACKAGE FINISH - 599

Service code - 599

    
  • Features
  • Specifications
  • Sample
  • Terms

Sl.

ITEM DESCRIPTION

PROCEDURE

MATERIAL

(See Sample)

OPENINGS & EDGE PROTECTION

 

Door Frames

Door Frame Fixing using holdfast as per Door & Window Schedule Specifications with maximum opening size of 1000 mm X 2100 mm. Max. Thickness of Frame shall be 2.5" and width shall be 4".

Door Frame:

Precast Frame (Cement Punned Finish & Painted) or Material with equivalent cost.

 

Window Frames

Window Frame Fixing as per Door & Window Schedule Specifications with Maximum opening size of 1200mm X 1300mm. Thickness of Frame shall be 2.5" and width shall be 4".

Window Frame:

Precast Frame (Cement Punned Finish & Painted) or Material with equivalent cost.

 

Main Door

Maximum one unit per floor. Single shutter of Size as per Door & Window Schedule Specifications and Design Selected from the Sample.

Designer type of Seasoned Wood with lac Polish

 

Main Door Fittings and Fixtures

Door Fixed with 3 Butt Hinge, 1 Aldrop Bolt, 2 Latch, 1 Tower Bolt, 2 Bow Handle, Mortise Lock, Door Stopper, PVC Buffer & Door Viewer.

Brass/ SS/ Aluminium Fittings (N.B: Only 1 Side Brass Fittings Set for each Main Door is Covered.)

 

Individual Room Doors

Single Shutter of size as per Door & Window Schedule Specifications and Design Selected from the Samples.

Membrane Doors/

Fibre Doors /Seasoned Wood

 

Individual Room Door Fittings & Fixtures

Door Fixed with 2 Butt Hinge, 1 Aldrop Bolt, 2 Latch, 1 Tower Bolt, 2 Bow Handle, Mortise Lock, Door Stopper, PVC Buffer & Door Viewer. As per Door & Window Schedule Specifications.

SS/ Aluminium Fittings

 

Window

Sliding/ Double Casement as per Door & Window Schedule Specifications and Design Selected from the Samples.

Composite Wood- Glass /Composite Powder Coated Aluminium Sliding Window with 5mm Dark Glass

 

Window Fittings and Fixtures

Window Fixed with 2 Butt Hinge, 2 Tower Bolt, 1 Bow Handle, 1 Wind Window Hook or Window Closure & Door Viewer.

SS/ Aluminium/ PVC Fittings

 

Bathroom Ventilator

Horizontally Pivoted or Louvered type ventilator of size as per Door & Window Schedule Specifications and designs selected from the samples.

Composite Wood- Glass /Composite Powder Coated Aluminium with 5mm Dark Glass

 

MS Grills for all Window/ Ventilator Openings

Either fixed using holdfast or screwed permanently across supporting structure. Design & enamel painted as selected from sample.

MS Section Grill painted with 1 coat Primer + 2 Coat enamel paint.

 

Other Openings

Sky light, AC Vent/ Gas Vent etc.

Composite MS Section + Glass/ Designer Precast

 

Balcony/ Stair Case Railing

Fixed with Anchor Bolts, Maximum Triple Layer and fixed type. Maximum Height shall be 3'2".

Stainless Steel/ Mild Steel Painted.

FLOORING & PAINTING

 

Paint (Interiors)

2 Coat Wall Putty + 1 Coat primer + 2 Coat Paint. Water paint ratio as per manufacturer guideline

Wall Putty

Primer

Paint

 

Paint (Exteriors)

1 Coat primer + 2 Coat Weather Proof Paint. Water paint ratio as per manufacturer guideline

Primer

Paint

 

Flooring for All Rooms/ Balconies

Mortar placing (1:6), cement Slurry Spreading, tile fixing and grout finish keeping zero slope gradient. Materials selected from Sample.

2' x 2' Vitrified Tiles

PPC Cement, Sand, Grouting Compound (Matching Tile Colour)

 

Bathroom Flooring

Mortar placing (1:6), cement Slurry Spreading, tile fixing and joint grout finish keeping slope gradient towards outlet drain. Materials selected from Sample.

2' x 2' Ceramic Tiles

PPC Cement, Sand, Grouting Compound (Matching Tile Colour)

 

Bathroom and Kitchen Wall Tiling

Mortar placing (1:6), cement Slurry Spreading, tile fixing and joint grout finish keeping zero slope gradient Materials selected from Sample. Maximum Up to 6' Height

8" x 12" Wall Tiles, PPC Cement, Sand, Grouting Compound (Matching Tile Colour)

 

Staircase Flooring

Mortar placing (1:6), cement Slurry Spreading, fixing and joint grout finish keeping zero slope gradient Materials selected from Sample.

Non Polish Marble/ Granite

 

Kitchen Counter Top

Mortar placing (1:6), cement Slurry Spreading, fixing and joint grout finish keeping zero slope gradient Materials selected from Sample.

Granite Counter Top

PLUMBING

 

N.B: In each floor area ranging from 1000Sqft to 2500 Sqft area, 1 Toilet, 1 Bathroom, 1 Kitchen, 1 Wash Basin are Covered.

 

Common Toilet

Equipped with S Trap 1 Sitting type Coupled Closet or1 20" Squatting Pan with outdoor PVC cistern unit (45 x 13 x 30.2 cm), 1 Wall Hung Basins, 1 Pillar Cock (Foam Flow) Faucet, 1 wall mixer (2 in 1) with provision for overheadshower, Single Flow Overhead shower,1 Bib Cock Faucet

All branded sanitary wares and faucets

 

Attached Bathroom

Equipped with S Trap 1 Sitting Type Coupled Closet or1 20" Squatting Pan with outdoor PVC cistern unit (45 x 13 x 30.2 cm), 1 Health Faucet, 1 Wall Hung Basins, 1 Pillar Cock (Foam Flow) Faucet, 1 wall mixer (3 in 1) with provision for overhead shower and hand shower, 1 200mm Rain shower, 1 Three Flow Hand Shower (150 mm), 1 Bib Cock Faucet

All branded sanitary wares and faucets

 

Common Accessories

1 Soap Dish Holder, Towel Bar& Bathroom Mirror

All branded accessories

 

Kitchen

1 SS Single Bowl Kitchen Sink, Sink Cock with normal swivel spout table/ wall mounted Faucet

All branded sink and faucet

 

Wash Basin

1 Single lever Basin Mixer, 1 Full Pedestal or Half Pedestal or Table Top Designer Basins.

All branded sanitary wares and faucet.

 

Plumbing Pipes Layout

Laying out as per MEP Specifications

UPVC Pipes, Joint Glue

 

Sanitary and RainWater Pipeline

One pipe system laying out as per MEP Specifications

PVC Pipes, Joint Glue

ELECTRICAL

 

Electrical Conducting

Laying out of Conduit pipes and installation of Fan Box all as per MEP Specifications

PVC Pipe

 

Electrical Wiring

As per MEP Specifications

Insulated Copper PVC Cable.

 

Switch Points, Bulb Points, Fan Point

All main points equipped with 6Switch, 1 5A/15A Socket, 1 Regulator, Single Switch points with 5A/ 15 A Points all as per MEP Specifications

Branded Modular Switches and points

 

MAIN DISTRIBUTION PANEL

All points connected to the main distribution box with individual room MCB switch

Branded Modular MCB panel Box

 

N.B: In each floor a maximum of 2 nos. of 15A Socket and 8 Nos 5A Socket are covered. Earthling wire is covered under the package but installation of Earthling System is charged extra as on actual.

Door &Window

Pine Wood Door

WPC Hollow Section Door

Wood Glass Composite or Powder Coated Al
Door Fittings

SS Door Handle

SS Door Handle

SS Tower Bolt

Door Stopper

Brass Aldrop

Brass Aldrop

Brass Tower Bolt

Door Stopper

SS Aldrop

SS Aldrop
Openings and Edge Protection

SS Staircase/ Balcony Railing

MS Grill

MS Balcony Railing
Paints

Asian Paints Tractor Emulsion

Berger Weatherproof

Berger Rangoli

JK Wall Putty
Vitrified Tiles/ Ceramic Tiles

Kajaria Tiles

Kajaria Tiles

Kajaria Tiles

Kajaria Tiles

Kajaria Tiles

Cera 2 in 1 Mixer
Faucet

Hindware Pillar Cock

HindwareSink Cock

Hindware3 in 1 Mixer

Cera Pillar Cock

Cera Pillar Cock

Cera Sink Cock

Cera Bib Cock

Cera Pillar Cock

CeraBib Cock

Renson Sink Cock

Cera Hand Shower

CeraHand Shower

Cera Overhead Shower

Cera Overhead Shower

Hindware Overhead Shower

CeraHealth Faucet

Hindware Health Faucet
Closet and Squat Pan

Hindware P Trap Closet

Cera P Trap Closet

HindwareOdisha Pan

Parryware Odisha Pan

HindwarePedestal Basin

Cera wall Hung Basin

SS Kitchen Sink
Sanitary & Plumbing Pipes cum fittings

Ashirad UPVC & CPVC Pipes

Watertec UPVC Fittings

Watertec UPVC Fittings
Electrical wires & Fixtures

Watertec UPVC Fittings

RR Kabel Cables & Wires

Anchor Roma Switches & Fixtures

Cona MCB Box

EXTRA WORKS

Ceiling Haller Design, Interior Designs, Landscaping works, Front elevation design and any other installation not mentioned in the list. 

 

  1. Any Construction Packages promoted under the brand of Builtify.in are liable for escalation in the below mentioned conditions:
  2. Abnormal price escalation (More than 1%) in the mid of project Execution or just after signing of contract due to any political reforms or Natural Catastrophe beyond the control of the Contractor. This condition is applicable for the likes of Raw Materials, transit Cost, Any Taxes Applicable, Petrol/ Diesel etc. 
  3. In case the Location of site lies or lead by a very congested neighbourhoodor the road leading to the site is not accessible by a minimum 5 MT Load Capacity Vehicles. In that case extra 0.5% shall be charged extra on the selected package.
  4. In case there is no space for storage of Bulk Raw Materials with in a lead of 15 Meter from the Work Site then 0.5% is shall be charged extra on the selected package.


GENERAL TERMS & CONDITIONS

  1. All the packages are applicable for construction done inside Bhubaneswar, Khurdha, Cuttack Revenue area.
  2. That in consideration of the payment by the owners to the contractor as per rate accepted by the contractor as herein after mentioned, the contractor hereby covenants with the owners to construct and complete work (core house) in the respect in conformity with the provisions of the contract within 8 months from the execution of this agreement.
  3. The contractor will not vary or deviate from the plans and specification without obtaining prior permission in writing of the owners.
  4. The contractor shall repair defects, shrinkage cracks or other faults that may appear in the work within six months after their completion.
  5. Both the parties agree by mutual consent that any dispute relating to this agreement is barred from arbitration. All problems shall be mutually and the decision of owners shall be final and binding on the contractor.
  6. In the event of any dispute that may arise out of this assessment the competent courts situated at Bhubaneswar shall have the authority to decide ad dispose of such dispute/ litigation between parties hereto.
  7. The measurement should be as per the roof area of the building.
  8. Any hindrances of payment made as per schedule by the party during execution or completion of the portion of the work. The work will be stopped until fulfilment of the condition made in the mode of payment.
  9. Increase work program deviate due to natural calamities and any other disturbances by miscreants or scarcity of material or labour strike.
  10. In case the work delayed due to non-payment of the bill in time the contractor will not be responsible.
  11. The work will be required to be completed within a period of 15 Calendar Months from the date of signing of the agreement, provided the payment will be made as per the condition of the mode of payment.
  12. The owners of the property have to be provided with electricity supply to the construction side during the execution of the work at their own cost.
  13. Payment will be made by cheque/ Cash as per work in progress and no escalation of price within the construction period.

GreenADDONs(Valid up to 1.1.2017)

  1. Rain Water Recharging Facility (N.B: Cost Partly Covered as per Government Scheme if applicable in your area)
  2. Motion Sensor Light for your Garage
  3. Kitchen Garden (5’x 2’) with selective plant.
  4. One time applying of Bio Sanitizer or digester for your Septic Tank or inspection Chamber.

 

N.B:You can choose any 1, from the above list. 


Copyright Oddaka Infratech (P) Ltd.
Design by CS web soluton
A Product of Oddaka Infratech (P) Ltd.                         Registered under Ministry of Corporate Affairs